← Manufacturing
Step 03 Etch & Strip

Wet Process Bench

Modutek Corporation, San Jose, CA, USA

HIGH ● Every wafer passes through wet chemistry multiple times

Role in QLT Fabrication

The wet process bench provides controlled chemical baths and DI rinse for all cleaning, developing, and stripping steps:

StepChemistryTemperatureTimePurpose
Pre-litho cleanAcetone → IPA → DI rinseRoom Temp2+2+2 minRemove organics before resist coat
Post-develop rinseDI water cascadeRoom Temp2 minStop MF-26A development
Post-etch cleanO₂ ash residue removal → IPARoom Temp5 minClean chip after RIE
Resist stripNMP (N-methylpyrrolidone) or acetone70°C10–30 minLift-off resist removal
Piranha cleanH₂SO₄:H₂O₂ (3:1)120°C10 minHeavy organic removal (if needed)
BHF dipBuffered HF (BOE 6:1)Room TempTimed (nm/min rate)SiO₂ etch / native oxide removal
Post-As₂S₃ etch cleanIPA → DI rinseRoom Temp5 minRemove etch residue [GAP03 only]

Process Criticality

  • Surface cleanliness directly determines resist adhesion, film quality, and optical performance
  • BHF etch precision controls SiO₂ removal rate ● critical for Poovey trench depth
  • Resist strip completeness prevents contamination of subsequent process steps
  • Cross-contamination between acid and solvent baths must be prevented by strict protocol

Chemical Compatibility Requirements

Bath TypeConstruction MaterialIncompatible Materials
HF / BOEPTFE (Teflon), HDPE, polypropyleneGlass, stainless steel, ceramics
Piranha (H₂SO₄/H₂O₂)Borosilicate glass (Pyrex), quartz, PTFEPolypropylene (at 120°C), metals
Solvents (acetone, IPA, NMP)Stainless steel, glass, polypropyleneSome plastics (acetone melts many)
Developer (MF-26A, TMAH)Polypropylene, PTFEMetals (TMAH etches Al)

Technical Specifications

StepChemistryTemperatureTimePurpose
Pre-litho cleanAcetone → IPA → DI rinseRoom Temp2+2+2 minRemove organics before resist coat
Post-develop rinseDI water cascadeRoom Temp2 minStop MF-26A development
Post-etch cleanO₂ ash residue removal → IPARoom Temp5 minClean chip after RIE
Resist stripNMP (N-methylpyrrolidone) or acetone70°C10–30 minLift-off resist removal
Piranha cleanH₂SO₄:H₂O₂ (3:1)120°C10 minHeavy organic removal (if needed)
BHF dipBuffered HF (BOE 6:1)Room TempTimed (nm/min rate)SiO₂ etch / native oxide removal
Post-As₂S₃ etch cleanIPA → DI rinseRoom Temp5 minRemove etch residue [GAP03 only]
Bath TypeConstruction MaterialIncompatible Materials
HF / BOEPTFE (Teflon), HDPE, polypropyleneGlass, stainless steel, ceramics
Piranha (H₂SO₄/H₂O₂)Borosilicate glass (Pyrex), quartz, PTFEPolypropylene (at 120°C), metals
Solvents (acetone, IPA, NMP)Stainless steel, glass, polypropyleneSome plastics (acetone melts many)
Developer (MF-26A, TMAH)Polypropylene, PTFEMetals (TMAH etches Al)
ParameterSpecification
ManufacturerModutek Corporation, San Jose, CA
TypeManual wet process station (operator-loaded)
ConstructionWhite polypropylene (acid side); stainless steel optional (solvent side)
Material complianceFM4910 compliant (fire-rated) materials standard; PVDF and Teflon options
Positions4–6 process baths + 1 QDR (Quick Dump Rinser) + 1 DI overflow rinse
Bath capacity5–10 L per position
Wafer handling100 mm Teflon cassette (25 wafers) or single-die holders
ExhaustIntegrated 1" lip exhaust on all process tanks + rear exhaust manifold
SafetyAll stations wired per NFPA 70 & 79; EPO with mushroom button; PVC safety shields
DI water18.2 MΩ·cm ultrapure supply required; continuous flow DI manifold
DrainChemical-resistant CPVC to acid neutralization
AccessoriesTeflon N₂ gun + DI water hand spray (standard); photohelic with interlock to EPO
SizingAvailable in any size and length to meet requirements
Warranty1-year on all parts; 2 copies paper manual + digital
OptionDescriptionRelevance for QLT
Silicon Nitride Etching BathsDedicated bath design for SiN processingDirectly applicable to our SiN waveguide clean
Sub-Ambient Baths for BOETemperature-controlled BHF baths for precise etch rateCritical for SiO₂ etch rate control
Quartz TanksFor Piranha and high-temperature processingNeeded if doing regular Piranha cleans
Teflon TanksFor HF/BOE processingRequired for our BHF etch step
Acid Fume ScrubberStandalone acid fume neutralizationPair with bench if building exhaust is insufficient
Acid Neutralization SystemInline neutralization before drainRequired by most jurisdictions for acid waste
Fan Filter Units (HEPA)Overhead HEPA filtrationISO Class 5 cleanliness over wafer handling
Seismic Zone 4 certificationStructural certification for earthquake zonesApplicable for California installations

Process Integration

Pre-Lithography Clean (Every Wafer, Before Resist Coat)

  • Don PPE: safety glasses, nitrile gloves, lab coat
  • Place wafer in acetone bath (Bath 1): 2 min soak with gentle agitation
  • Transfer to IPA bath (Bath 2): 2 min rinse (removes acetone residue)
  • Transfer to DI cascade rinse (Bath 7): 2 min overflow rinse
  • N₂ blow-dry using Teflon gun
  • Transfer to spin coater (#05) for resist coat

Post-Develop Rinse (After Mask Aligner Exposure + Develop)

  • After MF-26A develop (puddle or immersion, 60 s)
  • Transfer to DI cascade rinse: 2 min overflow
  • N₂ blow-dry
  • Inspect under microscope

Resist Strip (After Etch, to Remove Masking Layer)

  • Heat NMP bath (Bath 5) to 70°C; verify temperature with thermometer
  • Immerse wafer in NMP: 10–30 min (until resist fully dissolved)
  • Rinse in IPA bath: 2 min
  • DI cascade rinse: 2 min
  • N₂ blow-dry
  • Optional: O₂ plasma ash (if resist residue remains) ● use ICP-RIE (#01) at 0 W bias

BHF / BOE Dip (Oxide Etch)

  • CRITICAL: Full PPE for HF handling ● face shield, acid apron, long-cuff nitrile gloves
  • Buddy system required ● never handle HF alone
  • Verify calcium gluconate gel is accessible
  • Immerse wafer in BOE 6:1 (Bath 4): timed etch (SiO₂ rate ~100 nm/min at RT)
  • Quick transfer to QDR: dump-rinse 3 cycles
  • DI cascade rinse: 3 min
  • N₂ blow-dry immediately (native oxide regrows within minutes in air)

Piranha Clean (Heavy Organic Removal ● When Required)

  • CRITICAL: Never add H₂O₂ to warm H₂SO₄ ● always add H₂O₂ to cold H₂SO₄ and let reaction heat naturally
  • Mix 3:1 H₂SO₄:H₂O₂ in Pyrex or quartz beaker (NEVER in polypropylene)
  • Allow to self-heat to ~120°C
  • Immerse wafer: 10 min
  • Transfer to QDR: dump-rinse 5 cycles
  • DI cascade rinse: 5 min
  • N₂ blow-dry

Vendor Options & Pricing

New System Cost

ConfigurationEstimated New Price
Basic 4-position manual acid bench (polypropylene)$10,000–$20,000
6-position manual bench w/ QDR + DI rinse$18,000–$30,000
Dual-sided (acid + solvent) complete station$25,000–$45,000
Semi-automated with PLC + touchscreen + servo motors$40,000–$80,000
Terra Universal catalog fume hood (standalone)$5,000–$10,000

Where to Buy

VendorContactQuote Process
Modutek[email protected] / (866) 803-1533Consultative: provide process requirements → design review → quote
JST Manufacturingjstmfg.com/contactSimilar consultative process
Terra Universalterrauniversal.comCatalog items for direct purchase; custom also available
Cole-Parmercoleparmer.comIndividual PP baths, tanks, accessories for self-assembled bench
Sistem Technologysistemtechnology.comModutek authorized distributor (international)

Our Budget Recommendation

Buy NEW: $15,000–$20,000 (Modutek or JST custom 4-position acid bench)

  • Configuration: 4 bath positions (acetone, IPA, developer, BOE) + 1 QDR + DI cascade
  • Material: White polypropylene body; PTFE-lined baths for HF compatibility
  • Exhaust: Integrated 1" lip exhaust connected to building HVAC
  • Standards: FM4910 materials; NFPA 70 & 79 wiring; EPO; all safety interlocks
  • Lead time: 8–12 weeks from design signoff

Facility Requirements

Floor Space

DimensionRequirement
4-position bench footprint1.8 m × 0.7 m (72" × 28")
6-position with rinse2.4 m × 0.7 m (96" × 28")
Service access (front + rear)0.8 m clearance
Total floor requirement3.0 m × 2.3 m (7 m²)
Weight (empty)100–200 kg
Weight (filled with chemicals)200–400 kg

Electrical

ParameterRequirement
SupplySingle-phase, 120 V, 20 A
GFCIMANDATORY ● all outlets near wet bench
Separate circuitRecommended for heated baths

Power Consumption

ComponentPower Draw
Hot plate / immersion heater0.5–2.0 kW per heated bath
QDR controller0.05 kW
DI water system (if standalone)0.3–0.5 kW
Overhead lighting0.1 kW
TOTAL1.0–3.0 kW typical

Plumbing

UtilitySpecification
DI water supply18.2 MΩ·cm, 2–5 GPM
DI water connection½" PFA or PVDF tubing
Acid drainCANNOT go to regular sewer ● requires acid neutralization tank
Solvent drainSeparate collection for waste solvents (HazMat)
N₂ gunBlow-dry station; ¼" Swagelok from house N₂

Exhaust

ParameterSpecification
TypeIntegrated 1" lip exhaust + rear slot exhaust
Flow rate200–400 CFM total
Duct8" (200 mm) PVC or polypropylene to building HVAC
Face velocity80–120 fpm at operator breathing zone
ScrubberMay be required for HF (check local regs)

Vibration / Sound / Lighting

ParameterSpecification
Vibration sensitivityNONE
SoundQDR dump can be loud (70 dB burst); otherwise quiet
Special lightingYELLOW SAFELIGHT in developer area (same zone as aligner + spin coater)

Safety & Handling

Safety Equipment Requirements (CRITICAL)

RequirementSpecificationCost
Emergency eyewashANSI Z358.1 compliant; within 10 seconds travel$200–$500
Emergency showerANSI Z358.1 compliant; within 10 seconds travel$500–$1,500
Chemical splash gogglesFor all operators during acid/base handling$20 each
Face shieldFor Piranha or HF handling$30 each
Acid apronChemical-resistant PVC or rubber$30 each
Nitrile gloves (long-cuff)12" cuff for acid handling$15/box
Spill kitAcid neutralization + absorbent pads$200
SDS binderFor all chemicals used at benchRequired
HF antidote (calcium gluconate gel)MANDATORY if using BOE/HF$50
Total safety equipment$1,000–$2,500

HF Safety Protocol

HF (hydrofluoric acid, including buffered BOE) is uniquely dangerous:

  • Penetrates skin painlessly and causes deep tissue / bone destruction
  • Symptoms may be delayed 1–24 hours after exposure
  • Small-area burns can be fatal due to systemic fluoride poisoning

Mandatory controls:

  • Buddy system ● never handle HF alone
  • Calcium gluconate gel within arm's reach of BOE bath
  • Training ● all operators must complete institution-specific HF safety training
  • First aid protocol posted ● wash immediately with water (15 min); apply calcium gluconate; call 911 for any HF exposure
  • Dedicated PTFE bath with splash guards for BOE
  • PPE: face shield + acid apron + 12" nitrile gloves + closed-toe shoes

Hazard Summary

HazardRisk LevelControl
Chemical splash / acid burnMediumPPE mandatory; eyewash within 10 s; training
HF exposureLowCalcium gluconate; HF training; buddy system; dedicated bath
Cross-contaminationMediumSeparate acid/solvent sides; never share DI rinse
Solvent fire (acetone, MEK)LowNo open flames; fire extinguisher; solvent storage cabinet
Exhaust failure → fume exposureLowMonthly face velocity check; alarm on exhaust blower
← Back to Manufacturing
QLT