← Manufacturing
Step 05 Metallization

E-Beam Evaporator

HIGH ● Required for 48 electrical pads, heater interconnects, and SPAD contact bumps

Role in QLT Fabrication

The e-beam evaporator deposits a Ti (10 nm adhesion) / Au (200 nm conductor) bilayer by lift-off metallization on the foundry-returned SiN chip. This is the primary metallization tool ● all electrical connections between the quantum photonic processor and the external world pass through these metal layers.

Films Deposited

LayerMaterialThicknessPurpose
AdhesionTi10 nmPromotes Au adhesion to SiO₂ cladding surface
Contact padsAu200 nmWire-bonding pads (48 per die)
Heater leadsAu200 nm (with Ti adhesion)Routing from bond pads to TiN heaters
SPAD contactsAu (bumps)500 nm–2 μmUnder-bump metallization for flip-chip SPAD attach

Why E-Beam Evaporation

AdvantageExplanation
Ti melting point (1668°C)Thermal boats cannot reach this ● e-beam is required
DirectionalitySuperior line-of-sight deposition → clean lift-off sidewall profile
Multi-pocket hearthSequential Ti/Au deposition without breaking vacuum
High Au rate10–30 Å/s with excellent uniformity across substrate
Film purityNo Ar incorporation (unlike sputtering); important for wire bonding

Recommended Configuration

ParameterSpecification
ManufacturerFerrotec (Temescal Division), Livermore, CA
ModelFC-2000 (load-locked) / BJD-2000 (non-load-locked)
Websitetemescal.ferrotec.com
Contact[email protected]
Chamber20" bell jar, water-cooled stainless steel
Source-to-substrate distance19.5" standard; 27.5" with extension collar
E-beam gun270° deflection; 4×25cc PopTop turret + 1 fixed pocket
Power supplyCV-6SLX (6 kW) or CV-12SLX (12 kW), 10 kV
Sweep controllerTemEBeam Controller ● sweep, index, gun & HV
Load lockFC-2000: isolates source chamber from product chamber during substrate exchange
Product chamber cryopumpCT-400: 17,500 L/s
Source chamber cryopumpCT-8: 4,000 L/s
Pump-down time< 10 min to 1×10⁻⁶ Torr (FC-2000 with load lock)
Max wafer count42×2" wafers; 13×100 mm wafers (lift-off configuration)
Ion gunMKI filament (for pre-clean)
QCMInficon IC5 or IC6 deposition controller
ComplianceSECS/GEM capable; CE available
AdvantageExplanation
Ti melting point (1668°C)Thermal boats cannot reach this ● e-beam is required
DirectionalitySuperior line-of-sight deposition → clean lift-off sidewall profile
Multi-pocket hearthSequential Ti/Au deposition without breaking vacuum
High Au rate10–30 Å/s with excellent uniformity across substrate
Film purityNo Ar incorporation (unlike sputtering); important for wire bonding
ParameterSpecification
ManufacturerFerrotec (Temescal Division), Livermore, CA
ModelFC-2000 (load-locked) / BJD-2000 (non-load-locked)
Websitetemescal.ferrotec.com
Contact[email protected]
Chamber20" bell jar, water-cooled stainless steel
Source-to-substrate distance19.5" standard; 27.5" with extension collar
E-beam gun270° deflection; 4×25cc PopTop turret + 1 fixed pocket
Power supplyCV-6SLX (6 kW) or CV-12SLX (12 kW), 10 kV
Sweep controllerTemEBeam Controller ● sweep, index, gun & HV
Load lockFC-2000: isolates source chamber from product chamber during substrate exchange
Product chamber cryopumpCT-400: 17,500 L/s
Source chamber cryopumpCT-8: 4,000 L/s
Pump-down time< 10 min to 1×10⁻⁶ Torr (FC-2000 with load lock)
Max wafer count42×2" wafers; 13×100 mm wafers (lift-off configuration)
Ion gunMKI filament (for pre-clean)
QCMInficon IC5 or IC6 deposition controller
ComplianceSECS/GEM capable; CE available
ParameterSpecification
ManufacturerCHA Industries (now PlasmaTherm subsidiary), Livermore, CA
ModelMark 50 (ISS ● Isolated Source)
Websitechaindustries.com
Contact[email protected] / +1 (510) 683-8554
Chamber32" × 32" horizontal, water-cooled cylindrical
E-beam power6–15 kW (Telemark SX-10 aftermarket upgrade available)
Hearth4–6 pocket electron beam source
Ion gunIon pre-clean with AUTO controller
Substrate heaterUp to 400°C, multi-element
Ultimate vacuum10⁻⁸ Torr (chamber); 10⁻⁹ Torr (system)
Cryo coil50,000 L/s pumping speed for water vapor
Substrate domes4" and 6" dome options
Footprint79.5" W × 64" D × 78.5" H
UtilitiesAir 85–125 PSIG; water 10 GPM

Process Integration

QLT PROCESS FLOW ● E-Beam Evaporator (Steps B5/B9):

PRE-REQUISITES:
├── SiN chip with lift-off photoresist pattern (Step B4)
├── Resist profile: undercut sidewall for clean lift-off
└── Chip cleaned (O₂ plasma descum, 30 s)

STEP 1: Load Wafer
├── Mount chip on planetary dome (center position)
├── Load Ti pellets in pocket #1, Au slug in pocket #2
└── Close load lock (FC-2000) or main chamber (BJD-1800)

STEP 2: Pump Down
├── Rough to < 100 mTorr
├── Open gate valve to cryopump
├── Achieve < 5×10⁻⁷ Torr base pressure
└── FC-2000 load lock: < 10 min to 10⁻⁶ Torr

STEP 3: Ion Pre-Clean (Optional)
├── Ar+ ion gun: 500 eV, 2 min
└── Removes surface contaminants for better adhesion

STEP 4: Ti Deposition
├── Index hearth to Ti pocket
├── Ramp e-beam slowly; set sweep pattern for uniform melt
├── Open shutter at 1–2 Å/s rate
├── Deposit 10 nm (QCM controlled)
└── Close shutter

STEP 5: Au Deposition
├── Index hearth to Au pocket (without breaking vacuum)
├── Ramp to 10–20 Å/s
├── Open shutter; deposit 200 nm (or 500 nm–2 μm for SPAD bumps)
└── Close shutter

STEP 6: Cool & Unload
├── Wait 5 min for substrate cooling
├── Vent load lock with dry N₂
└── Remove chip for lift-off processing

STEP 7: Lift-Off
├── Immerse in acetone bath, 30 min with gentle ultrasonic
├── Rinse IPA → DI water → N₂ dry
└── Inspect under microscope; verify pattern integrity

Vendor Options & Pricing

New System Pricing

ModelConfigurationPrice (2025–2026)Lead Time
Temescal FC-2000 (load-locked, 6 kW)4-pocket PopTop, CT-400 cryo, QCM$250,000–$400,00016–24 weeks
CHA Mark 50 (ISS, 6–15 kW)4–6 pocket, ion pre-clean, domes$200,000–$350,00014–20 weeks
Angstrom Engineering Amod (e-beam config)Modern controls, configurable$150,000–$250,00012–16 weeks

Used/Refurbished Market (2025–2026 Listings)

Model"As-Is"Tested/FunctionalFull Refurb w/Warranty
Temescal FC-2000$20,000–$40,000$40,000–$70,000$70,000–$110,000
CHA Mark 50$45,000 (as-is, SemiStar listing)$100,000–$145,000$145,000–$189,500
CHA Mark 50 ISS (2021 Telemark upgrade)$189,500 (LabX listing, Feb 2026)
Temescal BJD-1800$8,000–$20,000$18,000–$35,000$30,000–$50,000
CHA SE-600$12,000–$25,000$25,000–$45,000$45,000–$70,000
Denton Explorer 14 (e-beam)$30,000–$50,000$50,000–$70,000

Active Marketplace Listings (as of Q1 2026)

SourceModelConditionPriceNotes
Moov TechnologiesTemescal FC-2000Used (multiple units)Contact for quotemoov.co
CAE OnlineTemescal BJD-1800 (16 offers)VariousRequest pricecaeonline.com
LabXCHA Mark 50 ISS (Palo Alto, CA)Refurb w/ Telemark SX-10$189,5002021 upgrade; Inficon IC6
SemiStarCHA Mark 50As-is from GaAs fab$145,000Morgan Hill, CA
ExaproCHA Mark 50 (vintage 2000)Good condition, testedPrice on requestUSA location

Vendor Directory

VendorTypeContactNotes
Ferrotec (Temescal)OEM + certified refurbtemescal.ferrotec.comOEM parts + support
CHA IndustriesOEMchaindustries.com / +1 (510) 683-8554Mark 50 OEM
Angstrom EngineeringOEM (new)angstromengineering.comModern Amod platform
ClassOne EquipmentRefurbished specialistclassoneequipment.com6–12 month warranty
LabXUsed marketplacelabx.comActive e-beam listings
Used-LineAggregatorused-line.comGood Temescal inventory
EquipXUsed marketplaceequipx.netCHA units common
Capovani BrothersUsed dealercapovani.comMajor NE dealer
Moov TechnologiesUsed semiconductormoov.coMultiple FC-2000 units
CAE OnlineUsed semiconductorcaeonline.com17+ Temescal models
SemiStarUsed dealersemistarcorp.comBay Area; CHA inventory

Price History

USED E-BEAM EVAPORATOR PRICE TREND (Temescal FC-2000 class):

2018-2019:  $25-50k (pre-COVID; moderate supply)
2020-2021:  $30-60k (tighter supply; labs retained equipment)
2022-2023:  $45-80k (peak: AI/packaging driving deposition demand)
2024-2025:  $40-70k (cooling from peak; more units entering market)
2025-2026:  $35-65k (favorable buyer's market ● GOOD TIME TO BUY)

CHA Mark 50 range: $45k-$190k depending on configuration and upgrades

TREND: E-beam evaporators are mature technology. Prices peaked during
the semiconductor boom but are declining as sputtering and ALD gain
market share for metallization.

Facility Requirements

Floor Space

DimensionRequirement
Main chamber footprint1.0 m × 1.0 m (40" × 40")
Power supply cabinet0.6 m × 0.6 m (adjacent)
Cryopump compressor0.5 m × 0.4 m (can be 3 m away)
Chiller0.5 m × 0.4 m
Service access0.8 m on 3 sides
Total floor allocation3.0 m × 2.5 m (7.5 m²)
Weight500–900 kg (1,100–2,000 lbs) ● reinforced floor or slab
CHA Mark 50 footprint79.5" W × 64" D × 78.5" H (2.0 × 1.6 × 2.0 m)

Electrical Requirements ● CRITICAL

ParameterRequirement
Supply3-phase, 208 V / 60 Hz ● MANDATORY
Circuit breaker80–100 A, 3-phase dedicated panel
CHA Mark 50120–208V/3ph/60Hz, 5-wire, 145 A
Wire gauge4 AWG per leg minimum
Dedicated panelYES ● separate from other equipment (prevent dips during e-beam ramp)
High-voltage10 kV internal ● ALL interlocks must be verified

Cooling Requirements

ParameterRequirement
Flow rate3–5 GPM total (gun + chamber walls + cryo compressor)
CHA Mark 5010 GPM total
Temperature18–22°C ± 1°C
SystemDedicated recirculating chiller ● MANDATORY
Chiller capacity5–10 kW thermal load
Chiller cost$3,000–$6,000

Environmental

ParameterSpecification
Vibration sensitivityMODERATE ● e-beam deflected by strong vibrations
FloorGround-floor concrete slab preferred
Separation≥ 2 m from roughing pumps; ≥ 3 m from dicing saw
Special lightingNot required (no photosensitive materials in this step)
ExceptionYellow safelight if loading resist-coated wafers
Cryopump noise65–75 dB(A) ● loudest component; runs continuously
MitigationLocate cryo compressor in utility chase or acoustic enclosure

Safety & Handling

Hazard Summary

HazardSourceRisk LevelControls
10 kV electric shockE-beam gun power supplyCRITICAL (LETHAL)All interlocks functional; LOTO for maintenance; trained personnel only
X-ray generation10 kV e-beam on targetLOW (< 12 kV, shielded by chamber)Chamber walls provide adequate shielding; no additional needed
BurnsMolten source material, hot chamberMEDIUMCool-down SOP; warning labels
Au spittingMolten Au splash during depositionMEDIUMProper sweep pattern; slow ramp
Cryopump compressor coolantHelium at high pressureLOWAnnual service by qualified technician

Safety Interlocks Required

  • HV power supply interlocked to all chamber access panels
  • Cryopump interlock (prevents operation without vacuum)
  • Water flow interlock (prevents gun operation without cooling)
  • Door interlock (prevents HV with chamber open)
  • Emergency stop (E-stop) readily accessible
← Back to Manufacturing
QLT

Protected Equipment Data

This page contains proprietary manufacturing specifications. Enter access code to continue.